FZOMU-SD 2.25 2x12xSML G652D

Description

Description

Standards

  • Product
    EN 187000; IEC 60794; IEC 60794-1
  • Test
    IEC 60793
  • International
    ITU-T Rec. G.650; ITU-T Rec. G.652

FZOMU-SD is a loose tube fibre optical cable and intended for outdoor use in ducts. The design can incorporate 6 -288 fibres in loose tubes (2.25mm). The individually coloured fibres are tubed in groups of 6 or 12 fibres, and stranded onto a central dielectric fibre reinforced strength member (FRP ). The cable type is longitudinal waterblocked through the use of swellable tape. The cable has an outer sheath of halogen- free black polyethylene.
 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Loose tube, SZ
Strength member
Central FRP
Fiber optic type
SM (G.652D)
Type of secondary protection
Loose tube
Material used for longitudinal water tightness
Swellable tape
Outer sheath
HDPE
Sheath colour
Black
Halogen free
Yes
Metal free
Yes
Length water tightness Tube
Jelly
Number of tube layer 1
6
Number of tube layer 2
0

Dimensional characteristics

Dimensional characteristics

Number of optical fibres
24
Nominal outer diameter
10.4 mm
Number of optical fibres, range
6 ... 288
Nominal outer sheath thickness
1.5 mm
Approximate weight
80 kg/m
Central strength member size
2.4 mm
Diameter over assembly
7.4 mm
Max. number of fibres per tube
12
Tube diameter
2.25 mm

Mechanical characteristics

Mechanical characteristics

Crush resistance (EN 187 000)
2 kN
Impact resistance (EN 187 000)
20 J
Maximum permanent tensile load
1 kN
Maximum pulling force by laying
2 kN

Usage characteristics

Usage characteristics

Installation type
Outdoor - Duct
Operating temperature, range
-45 ... 70 °C
Ambient installation temperature, range
-15 ... 60 °C
Storage temperature, range
-45 ... 70 °C
Bending factor when installed
10 (xD)
Dynamic bending factor
15 (xD)

Resources

Resources

Documentation

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close