Heatshrink Joint JTS1 WSK

Products

3x24JTS1.150MC-WSK 2.0

Nexans ref. 1030612

  • Packaging: Unit
  • Conductor cross-section, range: 35 ... 150 mm²
  • Diameter over insulation, range: 16 ... 26 mm
  • Length: 600 mm
  • Maximum outer diameter: 44.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.150MC-WSK2.0-VS

Nexans ref. VS1

  • Packaging: Unit
  • Conductor cross-section, range: 35 ... 150 mm²
  • Diameter over insulation, range: 16 ... 26 mm
  • Length: 600 mm
  • Maximum outer diameter: 44.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.150MC-WSK3.0

Nexans ref. Wrap1

  • Packaging: Unit
  • Conductor cross-section, range: 35 ... 150 mm²
  • Diameter over insulation, range: 16 ... 26 mm
  • Length: 600 mm
  • Maximum outer diameter: 44.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.240MC-WSK 2.0

Nexans ref. 1030567

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 20 ... 32 mm
  • Length: 600 mm
  • Maximum outer diameter: 46.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.240MC-WSK 2.0-VS

Nexans ref. VS2

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 20 ... 32 mm
  • Length: 600 mm
  • Maximum outer diameter: 46.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.240MC-WSK 3.0

Nexans ref. Wrap2

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 20 ... 32 mm
  • Length: 600 mm
  • Maximum outer diameter: 46.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.300MC-WSK 2.0

Nexans ref. 1030572

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 750 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.300MC-WSK 2.0-VS

Nexans ref. VS3

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 750 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.300MC-WSK 3.0

Nexans ref. Wrap3

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 750 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.400MC-WSK 2.0

Nexans ref. 1033045

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 24 ... 40 mm
  • Length: 750 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 32.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x24JTS1.95MC-WSK 2.0

Nexans ref. 1030574

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 16 ... 24 mm
  • Length: 600 mm
  • Maximum outer diameter: 40.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3x36JTS1.150MC-WSK2.0

Nexans ref. 1033047

  • Packaging: Unit
  • Conductor cross-section, range: 35 ... 150 mm²
  • Diameter over insulation, range: 20 ... 34 mm
  • Length: 750 mm
  • Maximum outer diameter: 46.0 mm
  • Minimum outer diameter: 30.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3x36JTS1.240MC-WSK 2.0

Nexans ref. 1032946

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 24 ... 38 mm
  • Length: 1000 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3x36JTS1.300MC-WSK 2.0

Nexans ref. 1032948

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 26 ... 40 mm
  • Length: 1000 mm
  • Maximum outer diameter: 58.0 mm
  • Minimum outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3x36JTS1.400MC-WSK 2.0

Nexans ref. 1032950

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 28 ... 44 mm
  • Length: 1000 mm
  • Maximum outer diameter: 62.0 mm
  • Minimum outer diameter: 38.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3x36JTS1.95MC-WSK 2.0

Nexans ref. 1032944

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 18 ... 32 mm
  • Length: 750 mm
  • Maximum outer diameter: 48.0 mm
  • Minimum outer diameter: 32.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

Description

Description

Standards

  • Product
    IEC 60502-4
  • Test
    CENELEC HD 629.1

Application

JTS1 WSK heat-shrink straight joints are designed for unarmoured, plastic insulated cables with AI tape screen, to accommodate either crimped or mechanical connectors.

Technical characteristics

JTS is the NEW high performance, compact and easy to install joint. A single body with all the electrical functions integrated!

Where as , 36-42JTS is double bodies with all the electrical functions integrated!

The Nexans “TRIPLE GT125” is an integrated stress control field, insulating and conductive tube, which can withstand high voltage applications up to 24kV and up to 400mm 2. From 400 up to 1200mm2 a double dual layer tube is utilized. “stress control field + insulating” nested in a coextruded high voltage applications up to 42kV.

A double layer pad with conductive rubber inside and HK orange mastic outside ensure a Faraday cage and smooth the effect of the electrical field and of the voltage gradient in the connector area.

The electrical continuity of the screen is ensured by a tinned copper stocking with roll constant force springs. The outer sheath is restored with heavy wall adhesive lined tubing.

 

Options

Vapor barrier available upon request (VS).

Wrap around sleeve, with Al foil, available upon request (WSK3.0).

Characteristics

Characteristics

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close